A glassy carbon electrode modified with a composite consisting of electrodeposited chitosan and carboxylated multi‑walled carbon nanotubes for simultaneous voltammetric determination of dopamine, sero
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국탄소학회
ㆍ수록지정보 : Carbon letters / 33권 / 7호
ㆍ저자명 : Shanshan Tang, Axin Liang, Miao Liu, Wei Wang, Fulai Zhang, Aiqin Luo
ㆍ저자명 : Shanshan Tang, Axin Liang, Miao Liu, Wei Wang, Fulai Zhang, Aiqin Luo
목차
A glassy carbon electrode modified with a composite consisting of electrodeposited chitosan and carboxylated multi-walled carbon nanotubes for simultaneous voltammetric determination of dopamine, serotonin and melatoninAbstract
1 Introduction
2 Materials and methods
2.1 Reagents and apparatus
2.2 Preparation of modified electrodes
2.3 Real samples preparation and detection
3 Results and discussion
3.1 Morphological characterization of working electrode
3.2 Electrochemical behaviour of DA, 5-HT and MT on working electrode
3.3 Optimization of operating conditions
3.3.1 Optimization of electrode preparation conditions
3.3.2 Optimization of detection conditions
3.4 Electrochemical active surface area
3.5 Effect of scan rate
3.6 Simultaneous detection of DA, 5-HT and MT
3.7 Reproducibility, repeatability and stability
3.8 Real sample analysis
4 Conclusion
References
영어 초록
A glassy carbon electrode modified with a composite consisting of electrodeposited chitosan and carboxylated multi-walled carbon nanotubes (e-CS/MWCNTs/GCE) was used as a working electrode for simultaneous determination of dopamine (DA), serotonin (5-HT) and melatonin (MT), which were related to circadian rhythms. The electrochemical characterizations of the working electrode were carried out via electrochemical impedance spectroscopy and chronocoulometry. It was found that electrochemical modification method, that was cyclic voltammetry, may can cause continuous CS polymerization on MWCNTs surface to form a dense membrane with more active sites on the electrode, and the electrochemically active surface area of e-CS/MWCNTs/GCE obtained was about 7 times that of GCE. The electrochemical behaviour of DA, 5-HT and MT on working electrode were carried out via differential pulse voltammetry and cyclic voltammetry. The results showed that e-CS/MWCNTs/GCE solved the problem that the bare electrode could not detect three substances simultaneously, and can catalyze oxidation potential difference as low as 0.17 V of two substances reaction at the same time, indicating very good electrocatalytic activity. By optimizing the detection conditions, the sensor showed a good linear response to DA, 5-HT and MT in the range of 20-1000 μmol/L, 9-1000 μmol/L and 20-1000 μmol/L, and the detection limits were 12 μmol/L, 10 μmol/L and 22 μmol/L (S/N = 3), respectively. In addition, the proposed sensor was successfully applied to the simultaneous detection of DA, 5-HT and MT in human saliva samples.참고 자료
없음"Carbon letters"의 다른 논문
- Interdependent factors influencing the carbon yield, st..13페이지
- Experiment and molecular simulation for liquid phase ad..15페이지
- Black phosphorus nanosheets‑based effective electrochem..9페이지
- Preparation and effect evaluation of rigid polyurethane..9페이지
- Fabrication of graphene‑assisted voltammetry platform f..10페이지
- A sandwich‑like CMC‑based/graphene/CMC‑based conductive..15페이지
- In‑situ growth of ZIF‑8/CP with ultra‑high adsorption c..11페이지
- A comparative study on metal species implanted amine–br..11페이지
- Investigation on thermal conductivity of dimethyl silic..7페이지
- Predicting the wear performance of graphene and silicon..26페이지