유한요소해석을 통한 현장 가열 재활용 시공 장비의 가열판 용량에 따른 아스팔트 포장의 열전도성 평가
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국도로학회
ㆍ수록지정보 : 한국도로학회논문집 / 18권 / 2호
ㆍ저자명 : 이강훈, 임진선, 정규동, 임정혁, 권수안, 김용주
ㆍ저자명 : 이강훈, 임진선, 정규동, 임정혁, 권수안, 김용주
목차
1. 서론2. 현장 가열 재활용 아스팔트 포장 공법
3. 미국 현장 가열 재활용 아스팔트 포장 시공 현장의 가열판 온도 측정
4. 유한요소해석
5. 실내 모형 시험을 통한 해석결과 검증
6. 결론
감사의 글
REFERENCES
영어 초록
PURPOSES: The national highways and expressways in Korea constitute a total length of 17,951 km. Of this total length of pavement, the asphalt pavement has significantly deteriorated, having been in service for over 10 years. Currently, hot in-place recycling (HIR) is used as the rehabilitation method for the distressed asphalt pavement. The deteriorated pavement becomes over-heated, however, owing to uncontrolled heating capacity during the pre-heating process of HIR in the field. METHODS: In order to determine the appropriate heating method and capacity of the pre-heater at the HIR process, the heating temperature of asphalt pavement is numerically simulated with the finite element software ABAQUS. Furthermore, the heating transfer effects are simulated in order to determine the inner temperature as a function of the heating system (IR and wire). This temperature is ascertained at 300 ℃, 400℃, 500℃, 600℃, 700°℃, and 800℃ from a slab asphalt specimen prepared in the laboratory. The inner temperature of this specimen is measured at the surface and five different depths (1 cm, 2 cm, 3 cm, 4 cm, and 5 cm) by using a data logger. RESULTS: The numerical simulation results of the asphalt pavement heating temperature indicate that this temperature is extremely sensitive to increases in the heating temperature. Moreover, after 10 min of heating, the pavement temperature is 36%~38% and 8%~10% of the target temperature at depths of 25 mm and 50 mm, respectively, from the surface. Therefore, in order to achieve the target temperature at a depth of 50 mm in the slab asphalt specimen, greater heating is required of the IR system compared to that of the gas. CONCLUSIONS : Numerical simulation, via the finite element method, can be readily used to analyze the appropriate heating method and theoretical basis of the HIR method. The IR system would provide the best heating method and capacity of HIR heating processes in the field.참고 자료
없음"한국도로학회논문집"의 다른 논문
- 자연친화적인 급내리막 직선부에서 GHG 배출지표에 근거한 속도유지표준화 형태의 교통정온화8페이지
- 대규모 미시교통시뮬레이션모형 구축을 위한 O/D 추정 방법 성능 비교 - 중력모형과 QUEENSOD..11페이지
- 한국형포장설계프로그램 및 유한요소해석을 이용한 동상방지층의 구조적 성능 평가8페이지
- 스프레이 패칭 긴급보수용 개질 유화 아스팔트와 100% 순환골재를 사용한 상온 아스팔트 혼합물의 성..11페이지
- 이산요소법을 이용한 수치해석에서의 상사성 이론의 적용성 검토10페이지
- 기계식 연속철근콘크리트포장의 현장 적용성 및 거동 분석 연구7페이지
- 도로동공 탐지를 위한 지표투과레이더의 적정 주파수 선정에 관한 연구6페이지
- 국내 현장중온재생공법의 효율적인 가열공정을 위한 기초연구8페이지
- 구조해석을 통한 터널내 줄눈 콘크리트 포장의 거동분석9페이지
- 터널내 온도조건을 고려한 콘크리트 포장의 거동 및 성능 평가8페이지