Comparison of Higher-Order Aberrations and Visual Quality in Eyes Wearing Aspheric and Spherical Silicone Hydrogel Contact Lenses
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 대한시과학회
ㆍ수록지정보 : 대한시과학회지 / 17권 / 3호
ㆍ저자명 : Jeong-Mee Kim, Koon-Ja Lee
ㆍ저자명 : Jeong-Mee Kim, Koon-Ja Lee
목차
Ⅰ. IntroductionⅡ. Methods
1. Subjects
2. Contact Lenses
3. Visual Acuity (VA)
4. Contrast Sensitivity (CS)
5. Wavefront higher-order aberrations(HOAs)
6. Pupillometry
7. Experimental procedure
8. Statistical analysis
Ⅲ. Results
1. Assessment of contact lens fit
2. Subjects
3. Visual Acuity
4. Contrast Sensitivity
5. Ocular higher-order aberrations
Ⅳ. Discussion
Ⅴ. Conclusions
References
한국어 초록
목 적: 비구면과 구면 실리콘하이드로겔 콘택트렌즈를 착용시킨 후 고위수차와 시력의 질을 비교 평가 하였다.방 법: 근시안 25명(나이: 24.32±2.87세)을 대상으로 Biofinity 비구면 실리콘하이드로겔 렌즈와 Acuvue Oasys 구면 실리콘하이드로겔 렌즈를 각각 착용시킨 후, 밝은 조명 (photopic)과 어두운(mesopic) 조명 상태에서, 고대비 및 저대비 시력검사와 3, 6, 12, 18의 공간주파수를 포함하는 대비감도검사를 시행하 였다. 파면수차 분석기를 이용하여 4 mm와 6 mm의 동공 크기에 따른 눈의 고위수차를 렌즈 착용 전과 렌즈 착용 상태에서 각각 측정하였고, 이틀 동안 하루에 한 종류의 렌즈를 착용하였으며 모든 검사는 단안으로 이루어졌다.
결 과: 밝은 조명과 어두운 조명 상태에서 검사한 고대비시력과 저대비시력은 비구면렌즈와 구면렌즈 사이에서 통계적으로 유의한 차이가 없었다. 대비감도는 어두운 조명 상태의 공간 주파수 12cpd에서 두 렌즈 디자인 사이에 유의한 차이가 보였지만(p=0.012), 다른 공간주파수 에서는 조명 상태에 상관없이 유의한 차이가 없었다. 두 종류의 렌즈를 착용한 후 각각의 고위수차 양은 4 mm와 6 mm 동공크기 모두에서 렌즈 착용 전의 고위수차 양를 감소시킨 것으로 나타났으며, 두 렌즈 디자인 사이에서 구면수차만 통계적으로 유의 한 차이가 있었고(4 mm 동공에서 p=0.002; 6 mm 동공에서 p=0.001), 다른 고위수차들은 동공크기에 관계없이 유의한 차이가 없었다.
결 론: 비구면 디자인의 실리콘하이드로겔 콘택트렌즈는 구면 실리콘하이드로겔 렌즈와 비교하여 임상적으로 시력의 질은 차이가 없는 것으로 나타났다.
영어 초록
Purpose: To investigate ocular higher-order aberrations (HOAs) and visual quality when wearing aspheric and spherical silicone hydrogel contact lenses.Methods: Fifty eyes of 25 myopic subjects (24.32±2.87 years; 13 females, 12 males) participated in this study. Each eye was fitted with two silicone hydrogel lenses of the following brands: Biofinity (aspheric design) and Acuvue Oasys (spherical design). Best-corrected visual acuity (VA) with high and low contrast and best-corrected contrast sensitivity (CS) at 3, 6, 12 and 18 cycles per degree (cpd) were measured under photopic and mesopic conditions. A wavefront analyzer was used to measure ocular HOAs for 4-mm and 6-mm pupils in each eye without and with the contact lenses. All measurements were conducted monocularly by having each subject to wear one lens design per one day during two days.
Results: No statistically significant differences in high contrast or low contrast visual acuity (HCVA or LCVA) were found between the two lens designs under photopic and mesopic conditions. There were no significant differences in CS under photopic or mesopic conditions at other spatial frequencies, although CS under the mesopic conditions at 12 cpd was statistically significant difference between the two lens designs (p=0.012). For ocular HOAs, the level of all HOAs with 4-mm and 6-mm pupils was reduced by two lens designs compared to wearing no lens. Also, there was statistically significant difference in spherical aberration (SA) between the two lens designs within the brands with both pupil sizes (p=0.002, p=0.001, respectively); however, there were no significant differences in any other ocular HOAs between the two lens types with 4-mm or 6-mm pupils.
Conclusion: Aspheric silicone hydrogel contact lenses are not clinically different in visual quality compared with spherical silicone hydrogel contact lenses.
참고 자료
없음태그
"대한시과학회지"의 다른 논문
- Electroencephalography (EEG) assessment of the wearing ..7페이지
- 조절마비제인 CyclogylⓇ 과 AtropineⓇ 이 배양 결막세포에 미치는 영향10페이지
- 외안근 고유수용감각 수준 평가를 위한 Maindot 검사의 적합성 연구12페이지
- 주시시차 시표에 따른 원거리 및 근거리 자각적 교정 값의 비교10페이지
- 초기, 중기, 말기 녹내장 환자에서 양안시기능 변화12페이지
- 콘텐츠별 스마트폰 사용과 스마트폰 중독이 조절기능에 미치는 영향10페이지
- 유아용 시력선별검사법에 관한 연구14페이지
- 다중 핀홀 안경에 의한 시력과 조절력 변화 효과에 대한 연구8페이지
- 성장기 아동 및 청소년기의 난시유병률 분석과 난시굴절력이 교정시력에 미치는 영향에 관한 연구10페이지
- 선글라스용 렌즈의 착색농도에 따른 시력의 변화8페이지