Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국전문물리치료학회
ㆍ수록지정보 : 한국전문물리치료학회지 / 22권 / 4호
ㆍ저자명 : Ui-jae Hwang, Sung-min Ha, In-chul Jeon, Sung-hoon Jung, Kyu-hwan Choi, Su-jung Kim, Oh-yun Kwon
ㆍ저자명 : Ui-jae Hwang, Sung-min Ha, In-chul Jeon, Sung-hoon Jung, Kyu-hwan Choi, Su-jung Kim, Oh-yun Kwon
목차
IntroductionMethods
Discussion
Conclusion
References
영어 초록
The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester’s hand over the subject’s clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B’s measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.참고 자료
없음"한국전문물리치료학회지"의 다른 논문
- Spatiotemporal Gait Parameters That Predict the Tinetti..7페이지
- Selective Muscle Activation With Visual Electromyograph..10페이지
- The Effects of Sciatic Nerve Mobilization on Hamstring ..9페이지
- Effect of Cervical Corrective Exercises on Pain, Neck P..7페이지
- Trunk Stabilization Exercise Using a Both Sides Utilize..8페이지